Part Number Hot Search : 
A3953SLB BA6798 E1001 B1222AD1 ADAV4622 TA8164P E741R041 DM74L
Product Description
Full Text Search
 

To Download T200XW01 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 1/24 no reproduction and redistribution allowed product specifications 20 wxga color tft-lcd module model name: T200XW01 (*) preliminary specifications ( ) final specifications
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 2/24 no reproduction and redistribution allowed contents interface connections 3-2 color input data refernece 3-5 precautions 8 packing 7 emc 6-2 cover contents record of revisions general description 1 absolute maximum ratings 2 electrical specifications 3 electrical charactreistics 3-1 signal timing specifications 3-3 signal timing waveforms 3-4 power sequence 3-6 optical sfecifications 4 mechanical characteristics 5 6 international standards safety 6-1 item no
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 3/24 no reproduction and redistribution allowed record of revision version date no old description new description remark 0.1 2004/08/10 0.2 2005/03/02 update spec 0.3 2005/5/18 upgrade response time to 8ms(gtg)
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 4/24 no reproduction and redistribution allowed 1. general description this specification applies to the 20 inch color tft-lcd module T200XW01. this lcd module has a tft active matrix type liquid crystal panel 1366x768 pixels, and diagonal size of 20 inch. this module supports 1366x768 wxga mode (non-interlace). each pixel is divided into red, green and blue sub-pixels or dots which are arranged in vertical stripes. gray scale or the brightness of the sub-pixel color is determined with a 8-bit gray scale signal for each dot. the T200XW01 has been designed to apply the 8-bit 1 channel lvds interface method. it is intended to support displays where high brightness, wide viewing angle, high color saturation, and high color depth are very important. * general information items specification unit note active screen size 20.04 inches display area 443.61(h) x 249.41(v) mm outline dimension 479.0(h) x 278.4(v) x 31.8(d) mm driver element a-si tft active matrix display colors 16.7m colors number of pixels 1366 x 768 pixel pixel arrangement rgb vertical stripe display mode normally black surface treatment hc, 3h
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 5/24 no reproduction and redistribution allowed 2. absolute maximum ratings the following are maximum values which, if exceeded, may cause faulty operation or damage to the unit. item symbol min max unit note logic/lcd drive voltage vdd -0.3 6 [volt] 1 input voltage of signal vin -0.3 (3.6) [volt] 1 operating temperature t op 0 +50 [ o c] 2 operating humidity h op 10 90 [%rh] 2 storage temperature t st -20 +60 [ o c] 2 storage humidity h st 10 90 [%rh] 2 note 1 : duration = 50msec note 2 : maximum wet-bulb should be 39 and no condensation.
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 6/24 no reproduction and redistribution allowed 3. electrical specification the T200XW01 requires two power inputs. one is employed to power the lcd electronics and to drive the tft array and liquid crystal. the second input which powers the ccfl, is typically generated by an inverter. 3-1 electrical characteristics values parameter symbol min typ max unit notes lcd: power supply input voltage vdd 4.5 5.0 5.5 vdc power supply input current idd - 0.71 0.95 a 1 power consumption pc - 3.6 4.8 watt 1 inrush current i rush - - 2.4 a 1 backlight power consumption - 47 - watt 2 life time 50000 60000 hours 3 the performance of the lamp in lcm, for example life time or brightness, is extremely influenced by the characteristics of the dc-ac inverter. so all the parameters of an inverter should be carefully designed so as not to produce too much leakage current from high-voltage output of the inverter. when you design or order the inverter, please make sure unwanted lighting caused by the mismatch of the lamp and the inverter (no lighting, flicker, etc) never occurs. when you confirm it, the lcd assembly should be operated in the same condition as installed in your instrument. do not attach a conducting tape to lamp connecting wire. if the lamp wire attach to conducting tape, tft-lcd module have a low luminance and the inverter has abnormal action because leakage current occurs between lamp wire and conducting tape. the relative humidity must not exceed 80% non-condensing at temperatures of 40 or less. at temperatures greater than 40 , the wet bulb temperature must not exceed 39 . when operate at low temperatures, the brightness of ccfl will drop and the lifetime of ccfl will be reduced. note : 1. vdd=5.0v, fv=75hz, f clk =86 mhz , 25 , vdd duration time= 470 s m the power supply input check patent definition and dissipation reference as below :
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 7/24 no reproduction and redistribution allowed horizontal 2 dot pattern 0.95a(max.) 1366*768*3 pixel pixel gray level 255 pixel gray level 0 horizontal 2 dot pattern (h-2-dot) rgbrgbrgbrgbrgbrgb white pattern 0.79a 1366*768*3 pixel pixel gray level 255 gray level 255 (white screen) rgbrgbrgbrgbrgbrgb black pattern 0.63a 1366*768*3 pixel pixel gray level 0 gray level 0 (black screen) rgbrgbrgbrgbrgbrgb vertical gray scale pattern 0.71a(typ.) 1366*768*3 pixel vertical gray scale r/g/b level 0~level 255 vertical grey scale pattern 2. the lamp power consumption shown above does include loss of external inverter at 25 . the used lamp current is the lamp typical current 3. the life is determined as the time at which luminance of the lamp is 50% compared to that of initial value at the typical lamp current on condition of continuous operating at 25 2 . the lamp current should fix in 4.5ma(typ.) and then keep the 60000hr(typ.) lamp life
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 8/24 no reproduction and redistribution allowed 3-2 interface connections - lcd connector (cn1): jae fi-x30ssl-hf or equivalent - lvds transmitter: sn75lvds83(texas instruments) or equivalent note: 1. all gnd (ground) pins should be connected together and should also be connected to the lcd s metal frame. all vcc (power input) pins should be connected together. no description no description 1 n.c. 16 gnd 2 n.c. 17 rx3- 3 n.c. 18 rx3+ 4 gnd 19 gnd 5 rx0- 20 n.c. 6 rx0+ 21 lvds option* 7 gnd 22 n.c. 8 rx1- 23 gnd 9 rx1+ 24 gnd 10 gnd 25 gnd 11 rx2- 26 vdd (+5v) 12 rx2+ 27 vdd (+5v) 13 gnd 28 vdd (+5v) 14 rxclk- 29 vdd (+5v) 15 rxclk+ 30 vdd (+5v) lvds option : h (3.3v) or nc ns (default) l (gnd) jetda
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 9/24 no reproduction and redistribution allowed backlight connector pin configuration electrical specification (lamp spec) parameter min typ max units condition ccfl current(icfl) 4.0 4.5 6.0 [ma] rms (ta=25 ) ccfl frequency(fcfl) 40 62 80 [khz] (ta=25 ) ccfl ignition voltage(vs) 1570 - - [volt] rms (ta= 0 ) ccfl voltage (reference) (vcfl) - 790 860 [volt] rms (ta=25 ) ccfl power consumption (pcfl) - 47 - [watt] (ta=25 ) lamp connect configuration (recommend) white pink (-) (+) inverter (-) (+) (+) (+) (-) (+) (-) pink white pink white pink white pink white pink white (-) (-) (+) module block diagram x1x2x3x4x5x6x7x8x9x10 y1 y2 y3 1366*(3)*768 dc-dc gamma front databack data y ctrl gamma d r a m auo-016 k1 timing controller lvds receiver source board control board lvds signal vdd inverter of 12 ccfl bl dc power
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 10/24 no reproduction and redistribution allowed 3-3 signal timing specifications this is the signal timing required at the input of the user connector. all of the interface signal timing should be satisfied with the following specifications for it s proper operation. * timing table item symbol min. typ. max. unit period tc 11.6 12.3 15.3 ns dclk freq. fc 54 81 86 mhz hsync freq. 1/th - - - khz vsync freq. 1/yv 50 60 75 hz period tv 776 840 1024 th vertical active tvd --- 768 --- th period th 1406 1606 2048 dclk horizontal active thd --- 1366 --- dclk *1) dclk signal input must be valid while power supply is applied. *2) display position is specific by the rise of enab signal only. horizontal display position is specified by the falling edge of 1 st dclk right after the rise of enab, is displayed on the left edge of the screen. vertical display position is specified by the rise of enab after a low level period equivalent to eight times of horizontal period. the 1 st data corresponding to one horizontal line after the rise the of enab is displayed at the top line of screen. 3.) if a period of enab high is less than 1366 dclk or less than 768 lines, the rest of the screen displays black. 4.) the display position does not fit to the screen if a period of enab high and the effective data period do not synchronize with each other.
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 11/24 no reproduction and redistribution allowed 3-4 signal timing waveforms tc
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 12/24 no reproduction and redistribution allowed 3-5 color input data reference the brightness of each primary color (red, green and blue) is based on the 8 bit gray scale data input for the color; the higher the binary input, the brighter the color. the table below provides a reference for color versus data input. color data reference input color data red msb lsb green msb lsb blue msb lsb color r7 r6 r5 r4 r3 r2 r1 r0 g7 g6 g5 g4 g3 g2 g1 g0 b7 b6 b5 b4 b3 b2 b1 b0 black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 red(255) 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 green(255) 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 blue(255) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 cyan 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 magenta 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 yellow 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 basic color white 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 red(000) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 red(001) 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ---- red(254) 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 red red(255) 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 green(000) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 green(001) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 ---- green(254) 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 green green(255) 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 blue(000) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 blue(001) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 ------- blue(254) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 blue blue(255) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 13/24 no reproduction and redistribution allowed 3-6 power sequence values parameter min. typ. max. units t1 470 - 1000 us t2 25 - 150 ms t3 650 - - ms t4 200 - - ms t5 50 - - ms t6 0.47 - 30 ms t7 1 - - s apply the lamp voltage within the lcd operating range. when the backlight turns on before the lcd operation or the lcd turns off before the backlight turns off, the display may momentarily become abnormal. caution : the above on/off sequence should be applied to avoid abnormal function in the display. in case of handling, make sure to turn off the power when you plug the cable into the input connector or pull the cable out of the connector.
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 14/24 no reproduction and redistribution allowed 4. optical specification optical characteristics are determined after the unit has been on and stable for approximately 30 minutes in a dark environment at 25 . the values specified are at an approximate distance 50cm from the lcd surface at a viewing angle of and equal to 0 . fig.4-1 optical measurement equipment and method values parameter symbol min. typ. max. units notes contrast ratio cr 650 800 1 surface luminance, white lwh 350 450 cd/ O 2 luminance variation white 5 p 1.25 3 response time (average) t 8 ms 4,5 (gray to gray) rise time tr (15) (18) ms decay time tf (10) (13) ms color coordinates red r x 0.643 r y 0.329 green g x 0.292 g y 0.587 blue b x 0.138 b y 0.074 white w x 0.284 w y typ.-0.03 0.295 typ.+0.03 viewing angle contrast ratio>10 x axis, right( =0 ) r 80 85 degree 6 x axis, left( =180 ) l 80 85 y axis, up( =90 ) u 80 85 y axis, down ( =0 ) d 80 85 pr880 or equivalent
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 15/24 no reproduction and redistribution allowed note: 1. contrast ratio (cr) is defined mathematically as: 2. surface luminance is luminance value at point 1 across the lcd surface 50cm from the surface with all pixels displaying white. from more information see fig 4-2. when i bl = 4.5ma, l wh =450cd/ O (typ.) l wh =lon1, where lon1 is the luminance with all pixels displaying white at center 1 location. fig.4-2 optical measurement point 3. the variation in surface luminance, white is defined (center of screen) as: white(5p) =maximum(l on1 , l on2 , ,l on5 )/minimum(l on1 , l on2 , l on5 ) 4. response time is the time required for the display to transition from white(l255) to black(l0) (decay time, tr d =tf) and from black(l0) to white(l255) (rise time, tr r =tr). for additional information see fig4-3. fig.4-3 response time contrast ratio (cr)= brightness on the "white" state brightness on the "black" state tr d tr r
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 16/24 no reproduction and redistribution allowed 5. the response time is defined as the following figure and shall be measured by switching the input signal for different gray level. for additional information see fig4-4 fig.4-4 response time 6. viewing angle is the angle at which the contrast ratio is greater than 10. the angles are determined for the horizontal or x axis and the vertical or y axis with respect to the z axis which is normal to the lcd surface. for more information see fig4-5. fig.4-5 viewing angle definition l0, l63, l127, l191, l255 l0, l63, l127, l191, l255 l0, l63, l127, l191, l255
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 17/24 no reproduction and redistribution allowed 5. mechanical characteristics the contents provide general mechanical characteristics for the model T200XW01. in addition the figures in the next page are detailed mechanical drawing of the lcd. horizontal (typ.) 479.0mm vertical (typ.) 278.4mm outline dimension depth (typ.) 31.8mm horizontal (typ.) 447.6mm bezel area vertical (typ.) 253.4mm horizontal 443.61mm active display area vertical 249.41mm weight 2000g (max.) surface treatment hc, 3h
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 18/24 no reproduction and redistribution allowed front view
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 19/24 no reproduction and redistribution allowed rear view
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 20/24 no reproduction and redistribution allowed 6. international standard 6-1. safety (1) ul6500, underwriters laboratories, inc. (auo file number : e204356) standard for safety of information technology equipment including electrical business equipment. (2) can/csa c22.2 no. 950-95 third edition, canadian standards association, jan. 28, 1995 standard for safety of information technology equipment including electrical business equipment. (3) en60950 : 1992+a2: 1993+a2: 1993+c3: 1995+a4: 1997+a11: 1997 iec 950: 1991+a1: 1992+a2: 1993+c3: 1995+a4:1996 iec 60065 european committee for electro technical standardization (cenelec) european standard for safety of information technology equipment including electrical business equipment. 6-2. emc a) ansi c63.4 methods of measurement of radio-noise emissions from low-voltage electrical and electrical equipment in the range of 9khz to 40ghz. american national standards institute(ansi), 1992 b) c.i.s.p.r limits and methods of measurement of radio interface characteristics of information technology equipment. international special committee on radio interference. c) en 55022 limits and methods of measurement of radio interface characteristics of information technology equipment. european committee for electrotechnical standardization. (cenelec), 1998
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 21/24 no reproduction and redistribution allowed 7. packing label sample carton label cushion set carton box, 320mm(w)x590mm(l)x410mm(h) carton no: customer no: made in taiwan taiwan model no: T200XW01 vx *pm100-01a1600001* qty: 6 part no: 97.20t02.xxx au o ptronics *tw4b999000180-zma02* model no: T200XW01 v.0 manufactured xx/xx au optronics 02xxx made in taiwan(ma) rating:xv ;xa *tw4b999000180-zma02* model no: T200XW01 v.0 manufactured xx/xx au optronics 02xxx made in taiwan(ma) rating:xv ;xa rating:xv ;xa
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 22/24 no reproduction and redistribution allowed pallet package air cargo : (3 *2) *3 layers, total 18 boxes with 108 pcs panel in one pallet top view side view ocean shipping : (3 *2) *5layers, total 30 boxes with 180 pcs panel in one pellet top view side view 120 530 940 1350 1000 1180 5 9 0 320 960 1200 1760 2170 1200 120 530 940 1350 1000 1180 590 320 960
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 23/24 no reproduction and redistribution allowed 8. precautions please pay attention to the followings when you use this tft lcd module. 8-1 mounting precautions (1) you must mount a module using holes arranged in four corners or four sides. (2) you should consider the mounting structure so that uneven force (ex. twisted stress) is not applied to module. and the case on which a module is mounted should have sufficient strength so that external force is not transmitted directly to the module. (3) please attach the surface transparent protective plate to the surface in order to protect the polarizer. transparent protective plate should have sufficient strength in order to the resist external force. (4) you should adopt radiation structure to satisfy the temperature specification. (5) acetic acid type and chlorine type materials for the cover case are not desirable because the former generates corrosive gas of attacking the polarizer at high temperature and the latter causes circuit break by electro-chemical reaction. (6) do not touch, push or rub the exposed polarizers with glass, tweezers or anything harder than hb pencil lead. and please do not rub with dust clothes with chemical treatment. do not touch the surface of polarizer for bare hand or greasy cloth. (some cosmetics are detrimental to the polarizer.) (7) when the surface becomes dusty, please wipe gently with absorbent cotton or other soft materials like chamois soaks with petroleum benzene. normal-hexane is recommended for cleaning the adhesives used to attach front/ rear polarizers. do not use acetone, toluene and alcohol because they cause chemical damage to the polarizer. (8) wipe off saliva or water drops as soon as possible. their long time contact with polarizer causes deformations and color fading. (9) do not open the case because inside circuits do not have sufficient strength. 8-2 operating precautions (1) the spike noise causes the mis-operation of circuits. it should be lower than following voltage: v= 200mv(over and under shoot voltage) (2) response time depends on the temperature. (in lower temperature, it becomes longer..) (3) brightness depends on the temperature. (in lower temperature, it becomes lower.) and in lower temperature, response time (required time that brightness is stable after turned on) becomes longer.
? copyright au optronics, inc. january, 2005 all rights reserved. T200XW01 ver0.2 24/24 no reproduction and redistribution allowed (4) be careful for condensation at sudden temperature change. condensation makes damage to polarizer or electrical contacted parts. and after fading condensation, smear or spot will occur. (5) when fixed patterns are displayed for a long time, remnant image is likely to occur. (6) module has high frequency circuits. sufficient suppression to the electromagnetic interference shall be done by system manufacturers. grounding and shielding methods may be important to minimize the interface. 8-3 electrostatic discharge control since a module is composed of electronic circuits, it is not strong to electrostatic discharge. make certain that treatment persons are connected to ground through wrist band etc. and don t touch interface pin directly. 8-4 precautions for strong light exposure strong light exposure causes degradation of polarizer and color filter. 8-5 storage when storing modules as spares for a long time, the following precautions are necessary. (1) store them in a dark place. do not expose the module to sunlight or fluorescent light. keep the temperature between 5 and 35 at normal humidity. (2) the polarizer surface should not come in contact with any other object. it is recommended that they be stored in the container in which they were shipped. 8-6 handling precautions for protection film (1) the protection film is attached to the bezel with a small masking tape. when the protection film is peeled off, static electricity is generated between the film and polarizer. this should be peeled off slowly and carefully by people who are electrically grounded and with well ion-blown equipment or in such a condition, etc. (2) when the module with protection film attached is stored for a long time, sometimes there remains a very small amount of flue still on the bezel after the protection film is peeled off. (3) you can remove the glue easily. when the glue remains on the bezel or its vestige is recognized, please wipe them off with absorbent cotton waste or other soft material like chamois soaked with normal-hexane.


▲Up To Search▲   

 
Price & Availability of T200XW01